<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>16058</ErrorNumber>
<ErrorFamily>Image</ErrorFamily>
<ErrorMessage>
IMAGE: requested laser power of %lu.%03lu Watts is above the limit of %lu.%03lu Watts
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Thermal</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The requested laser power before a plot was higher than the preset limit.  The
limit is hard-coded and dependent on the type of head (20W or 40W).  Both the
requested power and the limit are specified in the error message.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Check that the correct media type was selected for the current image, then try
the image again.  If the problem persists, call Creo Customer Support for help.
</text></DescriptionText>
<DescriptionText><text>
Or, if a laser power test series plot was started or underway, the requested
laser power was higher than the capabilities of the imaging head.  In this case,
specify a lower power level or a lower step increment value.
</text></DescriptionText>
</OperatorAction>
<Cause>
The NVS hdm wpower setting may be too high.
</Cause>
<Cause>
The workstation specified a media type that was not normally used, and has a
NVS hdm wpower setting that is too high.
</Cause>
<Cause>
A wpower series plot was started or underway, and the requested laser power
for the next series step was beyond the hard-coded limit for the current head
type.
</Cause>
<Cause>
The recorder has a lower power head than you think it has.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../commands/plot_wpower.xml</LinkAddress><LinkTitle>Command: plot wpower</LinkTitle></Link>
<Link><LinkAddress>../nvs/hdm_cal_wpower.xml</LinkAddress><LinkTitle>NVS: hdm wpower</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:31 2008 PST
</Updated>
<Links>
</Links>
</Error>